Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the wp-super-cache-clear-cache-menu domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/wp-includes/functions.php on line 6114

Notice: La función _load_textdomain_just_in_time ha sido llamada de forma incorrecta. Translation loading for the consultax domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Por favor, ve depuración en WordPress para más información. (Este mensaje fue añadido en la versión 6.7.0). in /var/www/wp-includes/functions.php on line 6114

Notice: La función _load_textdomain_just_in_time ha sido llamada de forma incorrecta. Translation loading for the kirki domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Por favor, ve depuración en WordPress para más información. (Este mensaje fue añadido en la versión 6.7.0). in /var/www/wp-includes/functions.php on line 6114
Evaluation of a new portable device that measures diameter of animal fibres – Fiberstech
Evaluation of a new portable device that measures diameter of animal fibres

Abstract

Increasing production of animal fibres has increased the need for a portable instrument that measures fibre diameter and associated characteristics with precision and accuracy. This research evaluated a new portable fibre tester (PFT) by measuring the diameter and related characteristics of tops and scoured fibres of wool, alpaca, and vicuña. The PFT was constructed with integrated mechanical, optical, electronic, and informatic components. Textile tops of sheep wool, alpaca fibres, and mohair goat fibres were used as standard references to calibrate the PFT and determine its accuracy and precision. The results were compared with those from a wool industry standard instrument (OFDA2000) that uses similar technology. The PFT had high accuracy (-0.01, -0.12, and -0.01 μm) for average fibre diameter (AFD) of wool, alpaca, and mohair fibres, respectively. Deviations of standard tops (ST) were within industry-accepted tolerance ranges. Standard errors, indicating precision, were low, ranging from 0.07 to 0.25 μm, 0.02 to 0.44 μm, and 0.09 to 0.024 μm, for wool, alpaca, and mohair fibre tops, respectively. The correlations of measurements of AFD from the two instruments were 0.99 for wool, alpaca, and mohair fibres, but lower for vicuña fibres (0.82). No evidence of bias was observed. Therefore, the PFT may be used as an alternative instrument for measuring fibre diameter and quantifying variation in diameter of wool, mohair, and alpaca fibres. The PFT has appeal for use in the field for practical animal selection and fleece classification based on fibre characteristics.

Keywords: alpaca, fibre diameter, mohair, vicuña, wool

es_PESpanish